Data Security
Allows changes to specific settings to be saved to the display memory. Writing to memory can be slow and each
change consumes 1 write of approximately 100,000 available. Set and save functions are always remembered.
Remember is off by default.
1 byte, 1 for on or 0 for off
254 202 245 160
FE CA F5 A0
Temporarily locks certain aspects of the display to ensure no inadvertent changes are made. A new level overrides
the old, and levels can be combined. Default is 0.
1 byte, each bit representing a level, see table below
Table 9: Data Lock Bits
Table 10: Lock Parameters
Unlocks all setting locks
Place holders only, should be 0
Locks settings such as backlight and contrast
Locks entire display, no new information can be displayed
1.36. Set and Save
Data Lock
254 203 245 160
FE CB F5 A0
Permanently locks certain aspects of the display to ensure no inadvertent changes are made. A new level
overrides the old, and levels can be combined. Default is 0.
1 byte, see data lock table