Environmental
Standard VFD Standard
Operating Temperature 0
o
C to +50
o
C
-20
o
C to +70
o
C
Storage Temperature
-10
o
C to +60
o
C -40
o
C to +80
o
C
Operating Relative Humidity Maximum 90% non-condensing Maximum 80% non-condensing
Table 13: DevDevil Environmental Specifications
Electrical
Current Consumption
Board
50mA
+
Backlight
20-115mA
+
Indicator GPOs
1.25mA each
+
Header GPOs
20mA each maximum
Table 14: DevDevil Current Consumption
Backlight Consumption
10. YG GW WB IY IR FW FB VFD*
20x2 105mA 40mA 45mA N/A 115mA 30mA 30mA 100mA
20x4 70mA 20mA 20mA 70mA N/A N/A N/A 100mA
Table 15: Backlight Current Consumption by Model
Optical
20x2 20x4 20x2 VFD 20x4 VFD units
Screen Size 116.0 x 37.0
98.0 x 60.0 116.0 x 37.0 98.0 x 60.0 mm
Viewing Area 83.0 x 18.6 76.0 x 25.2 N/A mm
Active Area 73.5 x 11.5 70.4 x 20.8 70.8 x 11.5 70.8 x 20.9 mm
Character Size 3.20 x 5.55 2.95 x 4.75 2.50 x 4.70 2.40 x 4.70 mm
Character Pitch 3.70 x 5.95 3.55 x 5.35 3.60 x 6.10 3.60 x 5.40 mm
Pixel Size 0.60 x 0.65 0.55 x 0.55 0.40 x 0.50 0.40 x 0.50 mm
Pixel Pitch 0.65 x 0.70 0.60 x 0.60 0.50 x 0.70 0.50 x 0.70 mm
Viewing Angle
-30
to +30
N/A
o
Luminance N/A 350 cd/m
2
Backlight Half-Life 50,000 N/A Hours
Table 16: DevDevil Optical Characteristics
*Note: A VFD style display will draw up to twice the normal operating current at start up inrush.